Coordinates are in metres, radius in millimetres. Any cell takes an expression: + − * / ( ) with R = λ at the design frequency, I = inch, F = foot, e.g. R/4 or 33*F. Wires connect where their end points coincide exactly. Seg: -1 tapers both ends (recommended), 0 automatic even, a positive number fixes the count.
Builds a straight element along Y from tube sections, centre outward: each section as half-length in metres × diameter in mm, for example 1.2x32, 1.2x25, 1.5x20, 1.55x16. The centre section becomes one wire across the middle (feed it at its centre, c), the others one wire per side. Sommerwire calculates the steps in diameter directly; see Help, Tube elements.
| # | X1 | Y1 | Z1 | X2 | Y2 | Z2 | R mm | Seg |
|---|
Position w1c = wire 1 centre, w1b = begin, w1e = end. Voltage sources. Balun n:1 puts an ideal transformer at the feed point (4 for a 4:1 unun, 49 for an EFHW's 49:1): the impedance and SWR are then those the feed line sees.
| # | Position | Phase ° | Volts | Balun n:1 |
|---|
Series L/C, a parallel L/C trap, or a fixed R + jX. Leave L or C at 0 to leave it out. Q is the coil's, Q C the capacitor's (empty = lossless); Cp is the coil's own self-capacitance, across the coil.
| # | Position | Type | L µH | C pF | Q | Q C | Cp pF | R Ω | X Ω |
|---|
A line between two feed points, connected across the gap at each end like NEC's TL card. It does not radiate or couple to the wires, so it suits coax. Leave Length empty for the straight distance between the ends; the velocity factor makes the line electrically longer. Loss is the matched loss in dB per 100 m from the cable's data sheet; with "at MHz" it is scaled to other frequencies with √f, without it the same loss is used at every frequency. Reversed swaps the two conductors at the far end. A source on a line end drives the line and the wire gap together.
| # | End 1 | End 2 | Z0 Ω | VF | Length m | Loss dB/100 m | at MHz | Reversed |
|---|
A house beside the antenna. X and Y are the centre of the footprint, Length runs along the ridge, Rotation turns the ridge away from the X axis. A metal roof is solved as a wire grid (mesh about λ/10 at the highest frequency or finer: 1 m suits HF); finer meshes are slower. Walls are shown for reference only: stone, brick and wood are not conductors, and a wire solver cannot model them. Metal gutters run along both eaves (not bonded to the roof); downpipes run from the gutter ends into the ground, each with an earth resistance (typically tens to hundreds of ohms at HF; 0 = perfect). If your downpipes end in plastic drains, choose None. Wiring or a steel frame can be drawn as wires. Add height on the Calculate tab lifts buildings too.
| # | X | Y | Length | Width | Wall height | Ridge height | Rotation ° | Roof | Mesh m | Gutters | Downpipes | Earth Ω |
|---|
With Real ground, the impedance is solved with Sommerfeld integrals, as NEC-2 does: exact for a flat homogeneous ground, so wires a few centimetres above the soil (radials, low dipoles, feed lines) come out right, ground loss included. "Complex image" is a faster approximation that underestimates ground loss closer to the soil than about 0.2 λ. "Perfect mirror" reproduces MININEC and MMANA-GAL. If any wire touches the ground, the whole impedance is solved over the perfect mirror; buried wires are not supported. The far field uses Fresnel reflection. Tapered segments run from λ/(SC·DM1) at wire ends to λ/DM2 in the middle.
Each calculation adds a row so you can compare changes. The newest row is highlighted.
| # | Antenna | MHz | R Ω | jX Ω | SWR | Max gain dBi | F/B dB | Elev ° | Ground | H m | Polarization | Unknowns |
|---|
Scale: dB relative to the maximum, rings at −3, −6, −10, −20 and −30 dB. Azimuth 0° is the +X axis, counter-clockwise, matching the top view.
Same scale as the plots above: distance from the centre is dB relative to the maximum, down to −40 dB, sampled every 5°. It follows the polarization chosen above ("Horizontal + vertical" and "All three" show the total field).
Choose what the optimizer may change and the range it may use. Moving a wire end also moves every wire end touching it, so connections stay intact. "Length, centre fixed" suits Yagi and dipole elements; "Length, begin fixed" suits legs and radials that start at the feed point.
| # | Change | Item | Axis / value | Now | Min | Max | Best |
|---|
No variables yet. Add one, or press "Add all wire lengths".
| Goal | Weight | Target | Effect |
|---|---|---|---|
| SWR | Penalises SWR above the target | ||
| jX | Pushes reactance toward zero (resonance) | ||
| Gain | Rewards forward gain, 3 dB per unit of weight | ||
| F/B | Rewards front-to-back up to the target (dB) | ||
| Elevation | Pulls the main lobe toward the target angle (°) |
Weight 0 switches a goal off. Gain, F/B and Elevation need a far-field search at every step, so each step takes longer. Results are averaged over the listed frequencies.
| MHz | R Ω | jX Ω | SWR | Gain dBi | F/B dB | Elev ° |
|---|
Loading help…